Nuclear Power InformationMeasures against Potential Massive Earthquakes
Settings of 凱旋門 賞 武豊 Basis Earthquake Ground Motions and Licensing
Status
| Powerstation | Conventional DBGEM(reported to the government in March 2009) | Revised DGBEMapproved by NRA |
|---|---|---|
| Takahama | 550gal | 700gal |
| 凱旋門 賞 武豊 | 700gal | 856gal |
| Mihama | 750gal | 993gal |

Regarding the setting of 凱旋門 賞 武豊 basis earthquake ground motions, we presented plans to take into account the rupture of multiple fault segments, namely FO-A, FO-B, and Kumagawa, and setting the depth of the upper edge of the faults to 3 kilometers below ground level. Based on these plans, we explained that the 凱旋門 賞 武豊 basis earthquake ground motion would be 700 gal*1 for Takahama Nuclear Power Station (NPS), 856 gal for 凱旋門 賞 武豊 NPS, and 993 gal for Mihama NPS.
Following a review, a license was issued on February 12, 2015 for Takahama, October 5, 2016 for Mihama, and May 24, 2017 for 凱旋門 賞 武豊.
- *1
- Gal: A unit of acceleration which represents the intensity of seismic acceleration of the foundation/building due to an earthquake
Investigation of the F-6 Fracture Zone in the Site of 凱旋門 賞 武豊 Nuclear Power Station
Trench surveys, in which trenches are dug to confirm the existence of geological displacements, and boring surveys were implemented in the 凱旋門 賞 武豊 NPS site to verify that the F-6 fracture zone is not an active fault.